Sterilwave 250
Because there’s always a machine to suit your needs
Can be installed in an existing plant room with minimal infrastructure work.
Technology
Why Sterilwave?
Sterilwave 250
The Sterilwave machine incorporates all the stages of medical waste treatment: shredding, microwave decontamination and cooling. Discover the different components that make up the machine.
| Equipment & accessories | Integrated shredder with rotating blades installed inside the vessel |
|---|---|
| 250-litre stainless-steel treatment vessel | |
| Human-Machine Interface (HMI) & Control system | |
| Electrical cabinet | |
| 1 step to load the waste manually | |
| Closed-loop cooling system | |
| Printer for operational traceability | |
| HEPA filter with 3-metre exhaust hose for steam exhaust | |
| Unloading container | |
| Electronic weighing system (optional) | |
| Loading | Manual (or automatic, optional) |
Customise the Sterilwave 250 with additional features
Depending on your needs, you can add extra features to your machine. Discover the available options.
Automatic loading system
The lifting system transfers medical waste into the treatment chamber. The standard model is specifically designed for the Sterilwave 250 and is compatible with 240-litre containers.
Electronic weighing system
Connected to the electrical control cabinet, the electronic weighing system transmits the weight of each batch of waste to the PLC. This data is stored on the memory card and printed on the traceability report at the end of each cycle.
Odour management
Three options available: an ozone generator controlled by the PLC, a condensation system using a cooled plate heat exchanger (12 kW), or a masking gel to be added manually before each cycle (approx. 10 g/cycle).
Biological indicators
Monitoring kit for periodically checking the effectiveness of the decontamination process (strips inoculated with Bacillus atrophaeus spores).
Spare parts and consumables
A personalised list of consumables and spare parts, including their estimated service life and maintenance recommendations, is drawn up based on your annual waste treatment volume.
Detailed specification sheet
| Technology | Shredding using rotary blades and microwave decontamination |
|---|---|
| Volume reduction | Up to 85% |
| Weight reduction | Up to 25% |
| Power supply | 400 V/three-phase, 50 Hz, 63 A – 100% electric |
| Final waste | Unrecognisable, inert, dry and stable |
| Main unit dimensions (L × W × H) | 2.4 m × 1.2 m × 1.7 m |
| Recommended ceiling height | 2.2 m (3 m with automatic loading) |
| Approximate weight | 1,200 kg |
Capacity estimated based on a waste density of 0.1 kg/L. Actual capacity may vary depending on the type of waste and does not include handling time between cycles. Adaptable to other electrical specifications on request.
Installation, commissioning and training
Service provided by a Sterilwave-certified technician at the customer's site
Preparation and Coordination
Our teams provide remote support to help prepare your site ahead of installation. We organise preliminary meetings, check technical requirements and coordinate the various stages with your local teams.
Equipment Installation
A Sterilwave-certified technician will visit your site to install the machine, carry out the necessary connections and perform technical checks to ensure that the equipment meets all operational and safety requirements.
Commissioning and Validation
Our technicians carry out the start-up, calibration and functional testing of your equipment. A full day of operation using actual waste allows us to verify its performance and validate its commissioning.
Staff training
We train your operators and technicians in the operation and maintenance of their equipment. The training covers operating procedures, safety guidelines, as well as preventive and corrective maintenance.